UVC Air Sanitizer

UVC Air Sanitizer

UVC Air Sanitizer – powered by UVpro

The current pandemic with the SARS-CoV-2 virus shows how important hygiene measures are to avoid its spread. The aerosols in the air are a major risk that can be reduced with UVC technology. Especially in public spaces such as event locations, waiting areas, conference rooms etc. The EXACT solutions UVC Air Sanitizer range can help to minimise the risk situations.

UVC light has the ability to inactivate the DNA/RNA of a life form. This works very efficiently on simple life forms such as viruses and bacteria. A commonly used value to define the efficiency of UVC products is the LD90 dose, which is defined as the UVC dose that kills 90% of the organism of a species. There is data available listing the needed radiation dose, depending on the virus type. In case of SARS-CoV-2 research has not yet concluded the needed radiation dose. Various sources indicate that the needed LD90 dose for SARS-CoV-2 is 4 mJ/cm² *². For a reduction rate of even up to 99,9 % the needed dose for corona viruses would result in a dose between 12 and 18 mJ/cm² *².

picture shows a V-LabE in a meeting room

Unfortunately, UVC light is also dangerous for human skin and eyes. As UVC Air Sanitizer products emit the UV light inside an encapsulated housing, nearly no UVC light is emitted outside the housing. The UVC Air sanitizer product range works by directing air through a housing which is equipped with UVC light emitting tubes. The used UVC tubes as well as the working principles are made and designed by the German company UVpro and are a warrant for reliability and efficiency. UVpro products are setting the market benchmark in sectors such as food industry and stand out in comparison with the widely used standard UVC emitting tubes.

By measuring the UVC energy inside our products as well as computer based scientific simulation we can define the UVC dose that our products deliver to the air that is guided through the housing. As a result we can estimate the resulting reduction rate of different viruses etc. As an addition we will shortly publish documentation of an independent laboratory testing those products. 

Finding the ideal position for the devices is key to maximum efficiency. It depends on the local situation such as air flow, ventilation, heating and of course room size. Furthermore dynamic factors like people and their behavior will have an effect. Please do not hesitate to contact us regarding any kind of question. 

 

As the products are designed and manufactured by EXACT solutions powered by UVpro we can also easily set up custom solutions. 

 

Key facts

  • cleans the air from viruses, bacteria and mould spores
  • high UVC doses
  • inactivates up to 99,9 % of corona viruses *²
  • different products depending on the application
  • external control and internal self-monitoring
  • easy setup, also for temporary installation
  • German engineering

 

The picture on the right side shows an example set up in an open space meeting area of about 800 qm³. Three units V1000E are mounted above the collaboration display. The air will be absorbed by the three systems which reduce the Corona virus load up to 99,9% and release the cleaned air back to the meeting space. 

IMG_9562-scaled

picture shows 3 units V1000E mounted above the display in an open space meeting area

*1  On June 8th 2020 the German Federal Ministry of Health has posted an offcial COVID-19 related update in which the importance of aerosol infection risk
      beside a droplet infection was confirmed.
*2  Exemplary values from the literature without guarantee and claim to completeness

For very large halls, multiple units can be combined to increase the maximum air volume. The products V300E and V1000E offer the possibility of external control by ethernet connection. V-LabE offers the programming of operating times.


V1000E [preliminary specifications]
UVpro tube 6 x 41 W
Total UVC output [W 253.7nm] 84
Air volume [m³/h] 250 / 800 (adjustable)
UVC dose [mJ/cm³] 12.5 / 6.5 (see air volume)
Corona reduction *² 99.9% / 99% (see air volume)
Noise emission [dB] max. 52
Mount 2 eye bolts
Size [mm] 1.092 x 314
Weight [kg] 27
Tube replacement interval [h] 12000 (75% +/- 5%) output performance
Supply voltage 230 V / 50 Hz
Input power [W] max 300
Operating temperature [°C] 0 – 35
Remote control LAN
Remarks logging of operating time/ power cycle

Please find below an overview of system accessories:

  • protective clothing
  • dosimeter (dose validation in a simple way)
  • lampchecker (measuring tool to determine the tube performance)
  • radiometer (measuring the prevailing UVC radiation)
  • safety tool (measuring the UV risk)

*² Exemplary values from the literature without guarantee and claim to completeness

For very large halls, multiple units can be combined to increase the maximum air volume. The products V300E and V1000E offer the possibility of external control by ethernet connection. V-LabE offers the programming of operating times.


V300E [preliminary specifications]
UVpro tube 2 x 41 W
Total UVC output [W 253.7nm] 28
Air volume [m³/h] 250
UVC dose [mJ/cm³] 6.5
Corona reduction *² 99%
Noise emission [dB] 41
Mount 2 eye bolts
Size [mm] 1.092 x 234
Weight [kg] 14.5
Tube replacement interval [h] 12000 (75% +/- 5%) output performance
Supply voltage 230 V / 50 Hz
Input power [W] max 100
Operating temperature [°C] 0 – 35
Remote control LAN
Remarks logging of operating time/ power cycle

Please find below an overview of system accessories:

  • protective clothing
  • dosimeter (dose validation in a simple way)
  • lampchecker (measuring tool to determine the tube performance)
  • radiometer (measuring the prevailing UVC radiation)
  • safety tool (measuring the UV risk)

*² Exemplary values from the literature without guarantee and claim to completeness

For very large halls, multiple units can be combined to increase the maximum air volume. The products V300E and V1000E offer the possibility of external control by ethernet connection. V-LabE offers the programming of operating times.


V-LabE [preliminary specifications]
UVpro tube 2 x 31 W
Total UVC output [W 253.7nm] 22
Air volume [m³/h] 0 – 100
UVC dose [mJ/cm³] 9.0
Corona reduction *² >99%
Noise emission [dB] max. 36
Mount wall mounting
Size [mm] 846 x 402 x 136
Weight [kg] 13.4
Tube replacement interval [h] 12000 (75% +/- 5%) output performance
Supply voltage 230 V / 50 Hz
Input power [W] 80
Operating temperature [°C] 0 – 35
Remote control -
Remarks sheduling of operating times

Please find below an overview of system accessories:

  • protective clothing
  • dosimeter (dose validation in a simple way)
  • lampchecker (measuring tool to determine the tube performance)
  • radiometer (measuring the prevailing UVC radiation)
  • safety tool (measuring the UV risk)

*² Exemplary values from the literature without guarantee and claim to completeness